Texas homeowners
Anti-siphon valve vs backflow preventer
Both stop sprinkler water flowing back into your drinking water. One protects a single zone; the other protects the whole system.
Fix your sprinklersOn this page
Both do the same job, in different places
Sprinkler water sits in the soil with fertilizer and whatever else is on the lawn. Backflow protection stops that water being pulled back into your home's drinking water when pressure drops. Texas requires it on every irrigation system connected to drinking water. An anti-siphon valve and a backflow preventer are two ways of providing it.
Anti-siphon valves
An anti-siphon valve is a zone valve with a small vacuum breaker built into the top. Each zone has its own. They sit above ground, usually in a row near the house. They must be installed at least 6 inches higher than the highest head on the zone, or they do not protect the water supply. You find them mostly on older systems.
Backflow prevention assemblies
A backflow prevention assembly is a single brass device that protects the whole system. It sits between the meter and the zone valves, which are in boxes in the ground. The common types are pressure vacuum breakers, double check assemblies and reduced pressure assemblies. They have test cocks so a licensed tester can check them, which is why water companies can require a yearly test.
How to tell which you have
Find where the sprinkler line leaves the meter or the house.
One brass assembly with small test taps on the side is a backflow prevention assembly.
A row of above-ground plastic valves with caps on top, one per zone, are anti-siphon valves.
Green valve boxes in the lawn mean in-ground valves, with one backflow assembly protecting them all.
Common problems
An anti-siphon valve spits water for a second when the zone starts. That is normal: the vent closes as pressure builds. If it keeps leaking while the zone runs, the vent seal is worn and the top needs rebuilding.
A backflow assembly drips or sprays after a freeze or with age. A cracked body must be replaced; worn internal parts can often be rebuilt.
Both freeze, because both sit above ground holding water. See our freeze guide.
Maintenance and testing
Keep both clear of soil, mulch and plants so they can vent and drain. Many water companies require the backflow assembly to be tested by a licensed tester on a schedule. In San Antonio, SAWS requires a yearly test on lawn irrigation systems. Your utility decides which devices it accepts on new systems. So ask before replacing one type with another.
Anti-siphon and backflow questions
Is an anti-siphon valve a backflow preventer?
It is one kind of backflow protection, built into a single zone valve. A backflow prevention assembly protects the whole system.
Why is my anti-siphon valve leaking from the top?
A brief spit at start-up is normal. Constant leaking while the zone runs means a worn vent seal.
Do anti-siphon valves need testing?
They have no test ports, so they cannot be tested like an assembly. Your utility's rules decide what is accepted.
Can I replace anti-siphon valves with one backflow preventer?
Often, as part of moving to in-ground valves. Check your water company's rules first.
Related pages
Start here: All sprinkler guides.
Also useful: How to program a sprinkler controller. Orbit sprinkler head or valve leaking. How to winterize a backflow preventer.
Need help? Sprinkler repair in San Antonio.
Need a hand?
SISCO repairs sprinkler valves across Greater San Antonio, Boerne and New Braunfels and can arrange a backflow inspection. Reach out to the irrigation experts at SISCO Irrigation at 210-697-9086 or see our valve guide.