How to winterize and insulate a backflow preventer
Drain first, then wrap. Wrapping alone leaves water in the brass to freeze.
Fix your sprinklersOn this page
Why the backflow preventer freezes first
The backflow preventer is the brass assembly where your sprinkler system connects to the water line. It usually sits above ground, in the wind, full of water. That makes it the part most at risk in a freeze. A cracked one sprays water until someone shuts it off. It must be replaced and retested.
Know which type you have
There are three common types, and each drains in its own way. A pressure vacuum breaker is tall, with a bell-shaped cap on top. A double check assembly is often in a box in the ground. A reduced pressure assembly has a relief port underneath. The make and model are on a tag or cast into the body. The manufacturer's manual for that exact model is the authority, and most are on the maker's website.
How to winterize it
Close the isolation valve that feeds the backflow preventer. The handle sits across the pipe when closed.
Drain the assembly by the steps in its manual. Opening the test cocks alone often does not empty it.
Leave the ball valves and test cocks in the positions the manual gives.
Wrap the assembly in dry insulation or a cover made for it, with a waterproof outer layer.
Switch the sprinkler controller to "off" so it does not try to run.
Good to know: here is one example. The maker's freeze manual for FEBCO Series 850 and 860 says to leave the ball valves half open, at 45 degrees, after draining. Other assemblies differ, so do not apply one model's steps to another. No manual, or not sure which type you have? Call a licensed irrigator or a licensed backflow tester.
How to insulate it
Use an insulated pouch made for backflow preventers. Or wrap every section in foam pipe wrap and put a waterproof cover over the whole thing. Keep the insulation dry: wet insulation against the brass does more harm than good. Insulation only slows freezing. So in a long freeze draining matters more than wrapping.
Would you like us to do it? See sprinkler winterization in San Antonio or backflow winterization in Boerne.
After the freeze
Leave the water off until everything has thawed. Restart the assembly by the start-up steps in its manual, opening the valves slowly. That is because water slammed into a cold assembly can crack it. Then look for any drip, spray or crack in the brass. If it leaks, shut the water off again. After a replacement, most water companies require a licensed tester to test the new assembly. In San Antonio, see backflow rules on our SAWS page.
Backflow freeze questions
At what temperature should I winterize my backflow preventer?
Whenever temperatures below 32 degrees Fahrenheit are forecast. Risk grows with how long it stays cold and with wind.
Is wrapping a backflow preventer enough?
No. Wrapping without draining leaves water in the brass to freeze. Drain first, then wrap.
How do I drain a backflow preventer?
By the steps in the manufacturer's manual for your exact model. The types drain differently.
Can a cracked backflow preventer be repaired?
A cracked body must be replaced. A cracked cover or check can sometimes be rebuilt with a kit.
Related pages
Start here: All sprinkler guides.
Also useful: Anti-siphon valve vs backflow preventer. How to program a sprinkler controller. How to find buried sprinkler heads.
Need help? Sprinkler repair in San Antonio.
Need a hand?
SISCO repairs freeze damage across Greater San Antonio, Boerne and New Braunfels. Reach out to the irrigation experts at SISCO Irrigation at 210-697-9086 or see our San Antonio freeze guide.
In Cordillera Ranch? The winter visit there is $275. See our winter offer.