One zone dead? Suspect its wire or solenoid. Every zone dead? Suspect the common wire.

Fix your sprinklers
On this page

How sprinkler wiring works

The controller sends 24 volts to each valve through a thin cable buried in the yard. One wire, the common, usually white, connects to every valve. Each valve also has its own zone wire, connected to a numbered terminal on the controller. A valve opens when power flows down its zone wire and back along the common.

Leer en español

What the symptoms tell you

One zone will not run, the others are fine: that zone's wire, its splice at the valve, or its solenoid.

No zone runs, but the display works: the common wire, or the transformer's output.

A zone works some days and not others: a corroded splice or a wire nicked by a shovel.

The controller shows a fault or a fuse blows: a short, where a zone wire touches the common or the ground.

How to test it

Unplug the controller before touching the wires.

  1. Check that each wire is tight under its terminal screw at the controller.

  2. Swap the dead zone's wire with a working zone's terminal, plug in and run it.

  3. Runs now? The controller terminal is bad. Still dead? The wire or solenoid is.

  4. With a multimeter on ohms, measure between the common and the zone wire at the controller.

  5. Roughly 20 to 60 ohms is healthy. Near zero is a short. No reading is a broken wire or solenoid.

Finding the break

Check the splices in the valve box first. Most wiring faults are there: splices made without waterproof connectors corrode. Remake them with waterproof wire connectors. If the splices are sound and the solenoid tests good at the valve, the wire is broken somewhere between the controller and the valve. Look where anyone has dug recently: new plants, a fence post, edging.

When to call

A break in the middle of a yard needs a wire locator to find. Technicians can also use a spare wire in the cable, if there is one, to bypass a damaged one.

Questions

How do I know if a sprinkler wire is broken?

One zone will not run and its solenoid tests good at the valve, or a multimeter shows no reading on that zone at the controller.

What voltage are sprinkler wires?

24 volts AC. Unplug the controller before working on them.

Why do none of my zones work?

Often the common wire, which every valve shares, or the transformer.

Can I splice a sprinkler wire?