Homeowners with a Hunter X-Core
Hunter X-Core controller: set it in six steps
The X-Core is a simple timer with one trap: extra start times. Here is how to set it and clear them.
Fix your sprinklersHow the X-Core works
The Hunter X-Core has a dial, four buttons and a PRG button. The plus and minus buttons change what is flashing. The arrows move to the next item. PRG picks the program: A, B or C.
Most homes need only program A, with one start time. One start time runs every zone, one after the next.
Set it in six steps
Dial to Current Time/Day. Set the year, month, day and time.
Dial to Start Times. Press PRG for program A. Set one start time.
Dial to Run Times. Set the minutes for each zone.
Dial to Water Days. Plus turns a day on. Minus turns it off.
Dial to Seasonal Adjustment. Leave it at 100 percent to start.
Dial back to Run.
Set your water day to match your water company's rules. In San Antonio, see the SAWS watering rules.
Sprinklers run twice? Remove the extra start time
This is the most common X-Core problem. Each program can hold four start times. Each one runs every zone again.
Dial to Start Times. Press the right arrow to see start times 2, 3 and 4. For each one you do not want, press minus until the screen reads OFF. OFF sits just before 12:00 AM. Then press PRG and check programs B and C the same way.
Seasonal adjust
Dial to Seasonal Adjustment. Plus and minus change the bars. Each bar is 10 percent. The range is 10 to 150 percent. Use it to cut every zone back in fall without changing each run time.
Run it by hand
One zone: dial to Manual, One Station. Pick the zone with the right arrow. Set the minutes. Turn the dial to Run.
All zones: leave the dial on Run. Hold the right arrow for 2 seconds. Program A starts.
The rain sensor switch
The X-Core has a sensor bypass switch inside the wiring cover. On bypass, the timer ignores the rain sensor. Use bypass to test, then switch it back.
What ERR means
A number and ERR, such as 1 ERR: a fault on that zone. It is most often the valve's solenoid or its wire.
P ERR: a fault on the pump or master valve wire.
ERR by itself: a fault on the remote plug.
A zone fault needs testing at the valve. See our valve guide.
Questions
How many programs does the Hunter X-Core have?
Three: A, B and C. Each can have up to four start times.
Why does my X-Core water twice?
There is a second start time, or a second program is set. Set the extra ones to OFF.
How do I turn off a start time on the X-Core?
Dial to Start Times and press minus until the screen reads OFF.
What does 1 ERR mean?
A fault on zone 1. Check the wire and the solenoid on that valve.
Related pages
Start here: Sprinkler parts and models.
Also useful: Hunter Pro-C controller. Rain Bird ESP-Me controller. Rain Bird DV valve.
Need help? Sprinkler repair in San Antonio.
Need a hand?
Still stuck, or seeing ERR? Reach out to the irrigation experts at SISCO Irrigation at 210-697-9086.